Serviços Personalizados
Journal
Artigo
Indicadores
- Citado por SciELO
- Acessos
Links relacionados
- Similares em SciELO
Compartilhar
Portugaliae Electrochimica Acta
versão impressa ISSN 0872-1904
Port. Electrochim. Acta v.23 n.3 Coimbra 2005
Development of a Voltammetric Method to Determine Molybdenum in Food Grains
A.L. Alvarado-Gámez1,2,* C. León-Rojas,2 E.R. Espinoza-Castellón1,2
1Centro de Electroquímica y Energía Química, 2Escuela de Química,Universidad de Costa Rica, Apdo. 2060, San Pedro de Montes de Oca, San José, Costa Rica.
Abstract
It was developed a very sensitive analytical method to determine molybdenum in water and food grains, using the linear sweep voltammetry technique, with adsorptive preconcentration of a Mo(VI) 8-hydroxyquinoline complex, in an acetate buffer media of pH = 3.5 and KClO3 0.5 mol/L as a support electrolyte. The linear range of the methodology goes from 1.0 hg/L to 10 mg/L, with a limit of detection of 0.3 hg/L and quantification of 1.0 hg/L. The methodology is suitable in the range of mg/L and hg/L. The method was applied to grinded samples of rice, beans, lentil seeds and chickpeas with the following result: 6.2 mg/kg in lentil seeds, 6.0 mg/kg in chickpeas, 3.2 mg/kg in red beans, and 1.7 mg/kg in rice.
Keywords: linear sweep voltammetry, complexes, trace analysis, molybdenum, 8- hydroxyquinoline, adsorptive preconcentration.
Resumen
Se desarrolló un método analítico muy sensible, para determinar molibdeno en agua y granos, utilizando la técnica de voltamperometría de barrido lineal, con preconcentración adsortiva de un complejo de Mo(VI) con 8 hidroxiquinoleína, en un medio de buffer de acetato de pH = 3.5 y KCIO3 0.5 mol/L como electrolito soporte. El ámbito lineal del método va desde 1.0 ηg/L hasta 10 µg/L, con un límite de detección de 0.3 ηg/L y de cuantificación de 1.0 ηg/L. El método resulta adecuado en el ámbito de µg/L y ηg/L. Se aplicó el método en muestras molidas de arroz, frijoles, lentejas y garbanzos y se logró cuantificar las siguientes cantidades: 6.2 mg/kg en lentejas, 6.0 mg/kg en garbanzos, 3.2 mg/kg en frijoles, y 1.7 mg/kg en arroz.
Palabras claves: voltamperometría de barrido lineal, complejos, análisis de trazas, molibdeno, 8 hidroxiquinoleína, preconcentración adsortiva.
Texto disponível em PDF
Full text only in PDF format
References
1. Z. Gao, K.S. Siow, Talanta 43 (1996) 719-726. [ Links ]
2. K. Yokoi, C. van den Berg, Anal. Chim. Acta 257 (1992) 293-299. [ Links ]
3. J.R. Turnlund, W.R. Keyes, G.L. Peiffer, G. Chiang, Am. J. Clin. Nutr. 61 (1995) 1102-1109. [ Links ]
4. Z. Navratilova, M. Kopanica, Anal. Chim. Acta 244 (1991) 193-196. [ Links ]
5. S. Sander, Fresenius J. Anal. Chem. 365(5) (1999) 435. [ Links ]
6. M. Karakaplan, G. Henze, Electroanalysis 5 (1993) 623-625. [ Links ]
7. M. Karakaplan, S. Gucer, G. Henze, Fresenius J. Anal. Chem. 342 (1992) 186-190. [ Links ]
8. Z. Gao, K. Siow, Mikrochimm. Acta 124 (1996) 211-218. [ Links ]
9. P. Farias, A. Ohara, A. Nóbrega, Electroanalysis 6 (1994) 333-339. [ Links ]
10. J.L. Jiang, Q. Gong, M. Liu, Anal. Letters 27 (1994) 1945-1954. [ Links ]
11. A.M. Alí, M.A. Ghandour, S.A. El Shatoury, S.M. Amed, Electroanalysis 12(2) (2000) 155. [ Links ]
12. I.C. Fraga, P.A. Farias, A.K. Ohara, Fresenius J. Anal. Chem. 366(3) (2000) 307. [ Links ]
13. A. Safavi, E. Shams, Anal. Chim. Acta 396(2-3) (1999) 215. [ Links ]
14. J.K. Taylor, Quality Assurance of Chemical Measurements, Lewis Publishers, Inc., USA. (1987) 159-163. [ Links ]
15. W. Horwitz, Anal. Chem. 54 (1982) 67A-76A. [ Links ]
16. W. Horwitz, R. Albert, J. Assoc. Anal. Chem. 68 (1985) 830-838. [ Links ]
* Corresponding author. E-mail address: agamez@cariari.ucr.ac.cr