SciELO - Scientific Electronic Library Online

 
vol.18 número2Transposição de veia ovárica como um tratamento cirúrgico menos invasivo para a síndrome de nutcrackerDoença cística adventicial da artéria popliteia: excisão sem reconstrução arterial índice de autoresíndice de assuntosPesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Angiologia e Cirurgia Vascular

versão impressa ISSN 1646-706X

Angiol Cir Vasc vol.18 no.2 Lisboa ago. 2022  Epub 30-Ago-2022

https://doi.org/10.48750/acv.426 

Case Report

On-table Zenith® CE Fenestrated Stent Graft modification for the treatment of delayed type Ia Endoleak

Fábio Pais1 
http://orcid.org/0000-0002-3058-7303

Anita Quintas1 

Gonçalo Alves1 

Joana Catarino1 
http://orcid.org/0000-0002-1559-5479

Ricardo Correia1 
http://orcid.org/0000-0002-0509-3715

Rita Bento1 

Rita Garcia1 
http://orcid.org/0000-0002-5135-0196

Rita Ferreira1 

Maria Emília Ferreira1 

1 Angiology and Vascular Surgery Department, Hospital de Santa Marta, Centro Hospitalar Universitário Lisboa Central, Lisbon, Portugal


Abstract

Introduction:

Delayed type Ia endoleaks are often associated with proximal extension of the aneurysmal degeneration to the juxtarenal aortic segment. Endovascular treatment of type Ia endoleaks secondary to aortic neck dilatation can raise many technical challenges related to the previous implanted stent graft.

Case report:

The authors present a clinical case of an 84 year-old man, with a past medical history of atrial fibrillation, acute ischemic stroke, hypertension and dyslipidemia, that initially underwent an EVAR for a 5.5.cm infrarenal AAA with a TREO Bolton® endograft. After 3 years of follow-up, the CTA scan showed a delayed type Ia endoleak secondary to aortic neck dilatation with significant growth of the aneurysmatic sac.

An endovascular proximal extension was planned, using a Zenith Fenestrated (ZFEN) platform (Cook Medical, Bloomington, Ind) but the short distance to the previous EVAR bifurcation did not allow the implantation of a standard 94cm CE fenestrated stent graft. To overcome this challenge, on-table modification of the fenestrated stent graft was performed by cutting the distal aortic stent. The stent graft was partially deployed on-table, the distal stent was cut with thermocautery, and the device was re-sheathed. The fenestrated cuff was then implanted in the standard fashion with target vessel catheterization and stenting. Two aortic covered stents (Aortic Begraft Bentley® 18mm) were implanted inside each iliac limb of the previous EVAR and sealed proximally in a parallel graft configuration on the fenestrated cuff.

The final completion angiogram demonstrated perfusion of the visceral arteries, resolution of the Ia endoleak and without further endoleaks, as well as perfusion of both hypogastric arteries. At two months of follow up, the patient remains asymptomatic and the CTA scan showed resolution of the type Ia endoleak but the presence of a late type II endoleak.

Discussion:

Delayed type Ia endoleaks associated with proximal extension of the aneurysmal degeneration to the juxtarenal aortic segment, can raise some technical difficulties related to the previous implanted stent graft. Careful evaluation of patient anatomy and previous endografts should be done in planning for these procedures. On table physician modification of stent grafts is a valid solution to overcome challenging cases limitations. Further long-term follow-up is needed.

Keywords: Type Ia endoleak; fenestrated stent graft; abdominal aortic aneurysm; juxtarenal; physician modified stent grafts

Introduction

Endovascular aneurysm repair (EVAR) has become a current standard of care for abdominal aortic aneurysms (AAA). Continuous development in endovascular treatment of aortic aneurysms, together with growing experience and encouraging results, have opened the way for a new generation of stent-grafts.1 However, the long-term success is limited by complications, most importantly endoleaks, that are associated with high reintervention rates. In case of a type Ia endoleak, which represents failure of achieving an adequate proximal seal, secondary intervention is strongly advocated to prevent secondary aneurysm rupture. Different treatment options are suggested such as endoanchors, parallel grafts like chimneys, fenestrated cuffs, embolization, or open conversion.2,3 A type Ia endoleak detected in the operative room can be promptly treated with adjunctive procedures.4 However, a delayed onset of this type of endoleak can reflect progression of the aneurysmatic disease. Dilatation of the proximal neck can occur, with expansion of the aneurysm, eventually resulting in a juxtarenal or pararenal AAA. Endovascular treatment of type Ia endoleaks secondary to aortic neck dilatation can raise many technical challenges related to the previous implanted stent graft.5 Catheterization difficulties are expected due to passage through the limbs or struts of the previous stent graft, in particular in the case of a previous graft with supra-renal fixation stent whose struts can challenge renal catheterization.12

On another hand inadequate working distance related with a short length from renal arteries to previous implanted EVAR bifurcation can increase the complexity of redo endovascular cases and may require creativity and flexibility in the design and deployment of these new devices.13

We describe a case where a physician-modified Zenith® fenestrated stent graft and two parallel aortic covered stents were used in reparing a delayed type Ia endoleak.

Case report

An 84-year-old man with a past medical history of smoking, atrial fibrillation, acute ischemic stroke, hypertension and dyslipidemia initially underwent an EVAR for a 55mm infrarenal AAA (with a straight neck of 22mm of diameter, without thrombus or calcification and a good landing zone) with a TREO Bolton® endograft.

The patient did not attend the next appointment after hospital discharge, and he was lost for follow-up. Three years after the initial EVAR, a CTA scan was performed showing a delayed type Ia endoleak secondary to aortic neck dilatation with significant growth of the aneurysm sac, with a maximum diameter of 9.8 cm (Figures 1 and 2). The patient remained asymptomatic.

Figure 1: CTA images showing type Ia endoleak. A: axial; B: coronal 

Figure 2: CTA images showing type Ia endoleak. A: Sagittal; B: 3D reconstruction volume rendering 

An endovascular proximal extension was planned, using a fenestrated cuff (ZFEN platform, Cook Medical, Bloomington, Ind) but the short distance from the top of the fenestrated cuff to the previous EVAR bifurcation did not allow the implantation of a standard Zenith® CE fenestrated stent graft (94cm stent graft length; top of ZFEN fabric to previous EVAR bifurcation 78cm length). To overcome this challenge, an on-table modification of the fenestrated stent graft (with 1 large strut fenestration for the SMA, 2 small fenestrations for the renals) was planned by cutting the distal aortic stent. Also, to overcome the short working distance from the lowest renal artery to the previous EVAR bifurcation, a parallel stent graft configuration using two aortic covered stents sealed in the fenestrated cuff and in each iliac limb of the previous EVAR was proposed.

The fenestrated endograft was partially deployed on-table, the distal stent was cut with thermocautery, and the device was re-sheathed. (Figures 3, 4)

Fig 3 A and B: Fenestrated stent graft partially deployed on-table and cutting the distal stent with thermocautery. 

Figure 4 A, B and C: The device being re-sheathed. 

Under general anaesthesia, percutaneous bilateral ultrasound guided access of the common femoral arteries was obtained. The fenestrated cuff was implanted in the standard fashion with target vessel catheterization and renal stenting (BeGraft® Bentley InnoMed GmbH 6mm). Two aortic covered stents (Begraft Aortic®stent Bentley InnoMed GmbH 18mmx48mm) were implanted inside each iliac limb of the previous EVAR and sealed proximally in a parallel graft configuration on the fenestrated cuff.

The final completion angiogram demonstrated perfusion of bilateral renal arteries, resolution of the Ia endoleak and without further endoleaks, as well as perfusion of both hypogastric arteries (Figure 5). At two months of follow-up, the patient remains asymptomatic and the angio-CT scan showed resolution of type Ia endoleak (figure 6) and the presence of a late type II endoleak.

Fig 5: Final completion angiogram. Deployed modified Zenith® CE Fenestrated Stent Graft with patent renal and visceral arteries and absence of endoleaks. 

Fig 6: Two-month post-operative follow-up CTA. A: Three-dimensional reconstruction of the Fenestrated Stent Graft with patent stents and resolution of type Ia endoleak; B: axial fenestrated stent graft at the level of the renal stents; C: Kissing aortic covered stents in parallel graft configuration) 

Discussion

Endovascular aneurysm repair has become the first-line treatment modality for infrarrenal aortic aneurysms.1 However, obtaining successful long-term results usually requires new interventions. While rarely some type I endoleaks may resolve spontaneously during follow-up, usually require prompt reintervention because of the risk of aneurysm expansion and rupture.7 Delayed type Ia endoleaks require challenging interventions, because they are frequently associated with proximal extension of the aneurysmal process to juxtarenal or pararenal aortic segments.6

Many endovascular techniques are available to address the treatment of type Ia endoleaks. The proximal extension with a fenestrated stent graft (FEVAR) is one of the definite solutions for the repair of juxtarenal abdominal aortic aneurysm after prior EVAR failure.10,11 This was the preferred treatment approach chosen for the described case, that considered factors as age, clinical and anatomic characteristics and time required for graft customization. In this case, the proximal neck was a straight neck, without thrombus or calcification with a good landing zone, thus with a theoretically expected lower probability of proximal extension of the aneurysmal aortic degeneration.

FEVAR after EVAR can raise many technical challenges such catheterization difficulties or the presence of an inadequate working distance to previous implanted EVAR bifurcation.10,11 When this working space is not available, the usual alternative is a branched endograft, that brings the disadvantages of a more extensive proximal aortic coverage. To overcome this issue, it is described the successful off the shelf usage of a physician modified ZFEN stent graft whose length was adapted to the patient anatomy by cutting the distal stent on table. In the described case considering ZFEN platform, the short fenestrated cuff available with two proximal internal sealing stents was 94cm length. This was modified to be shorter by cutting the distal stent to adapt to patient’s anatomy measurements (ZFEN top fabric to the previous EVAR length 78cm). We decided to use two balloon-expendable covered stents - implanted inside each iliac limb and sealed proximally in a parallel graft configuration in the fenestrated cuff - instead of self-expendable stents because of a better deployment and alignment with the renal stents of the FEVAR. These two stents were implanted to improve the extension of the landing zone and eventually the durability.

Another frequent technical issue encountered during FEVAR after EVAR failure is the insufficient distal seal in the previous stent graft and the lack of adequate working length required for complete relining with a fenestrated cuff and bifurcated device, especially with previous devices featuring a short body.12 This potential short working length from the lowest renal artery to the previous EVAR bifurcation is usually overcome with a custom made bifurcated stent graft incorporating an inverted limb. To overcome the cost and manufacturing time of this component and as an alternative to achieve the distal seal of the fenestrated stent graft the authors described the use of two parallel covered stents extended to each iliac limb in a kissing like configuration. This can be an alternative to the inverted limb bifurcated stent graft unibody. Another solution for this issue described in the literature is a custom-made 5-branch device (Cook Medical, Bloomington, IN, USA) tapered and featuring an additional posterior branch used for sealing in the contralateral iliac limb.14 However, as already mentioned, branched stent-grafts may require a more extensive aortic coverage, increasing the risk of spinal cord ischemia.14

On-table physician stent-graft modifications have been greatly described in literature, as off-the-shelf ultimate solutions to adjust complex patient anatomies. Most of the reported physician modified stent-grafts describe on-table in situ stent-graft fenestrations for visceral target vessels. In a recent report Paludetto et al.15 described a two case experience, in which the use of physician modified off-the-shelf endografts appears to be a feasible and effective alternative to fenestrated endovascular repair in patients with juxtarenal abdominal aortic aneurysms at high risk for open surgical repair. In 2012, Starnes W. B. conducted a retrospective, nonrandomized, single institution evaluation of the safety and efficacy of physician modification of a currently Food and Drug Administration-approved device to preserve branch vessels when used in the treatment of patients with elective, symptomatic, or ruptured juxtarenal aortic aneurysms.16 In this study, the investigators followed 47 consecutive patients underwent fenestrated endovascular repair using physician modified fenestrated stent grafts over a 3-year period. On follow-up, six patients (13%) had endoleak. There was one type 1 endoleak and five type 2 endoleaks. There were two deaths in the first year, one in the second year, and zero in the most recent year of experience. One patient with endoleak (2%) had aneurysm sac expansion at 1 year requiring secondary intervention. They concluded that physician-modified endovascular grafts are a safe and effective alternative for treating patients with juxtarenal aneurysms who have no other alternatives for repair. Longer-term follow-up is needed to assess the durability of repair and potential for device-related complications It is the author’s that device modification should be performed only at centers completely familiar with all advanced endovascular aortic and visceral artery techniques and a high volume of these fenestrated procedures, as in our hospital centre.16

In conclusion, we report a successful advanced technique using an off-the-shelf physician modified fenestrated stent graft to repair a delayed type Ia endoleak and maintain renal perfusion in a patient with a previous implanted stent graft. Careful evaluation of patient anatomy and previous endografts should be done in planning for these procedures. On-table modification of stent grafts is a valid solution to overcome challenging limitations. Short-term results are promising using this approach, but further long-term follow-up is needed to determine the durability and the potential for device-related complications.

Acknowledgements

None

Conflicts of interest:

None

Funding

None

References

1. Dua A, Kuy S, Lee CJ, Upchurch GR, Desai SS. Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010. J Vasc Surg. 2014;59:1512-17. [ Links ]

2. Schaik T, Meekel J, Hoksbergen A, Vries R, Blankensteinjn J, Yeung K. Systematic review of embolization of type I endoleaks using liquid embolic agents. J Vasc Surg 2021;74:1-9. [ Links ]

3. Veith F, Baum R, Ohki T, Amor M, Adiseshiah M, Blankensteinjn J et al. Nature and significance of endoleaks and endotension: summary of opinions expressed at international conference. J Vasc Surg 2002;35:1029-35. [ Links ]

4. Rosen R, Green R. Endoleak management following endovascular aneurysm repair. J Vasc Interv Radiol. 2008;19:37-43. [ Links ]

5. Harris P, Vallabhaneni S, Desgranges P, Becquemin J, Marrewijk C, Laheij R. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg. 2000;32:739-49. [ Links ]

6. Reddy N, Ham S, Weaver F, Rowe V, Ziegler K, Han S. Repair of Delayed Type 1a Endoleak using Fenestrated and Parallel Endografts. Ann Vasc Surg. 201849:309.e7-e15 [ Links ]

7. Chaikof E, Brewster D, Dalman R, Makaroun M, Illig K, Sicard G et al. SVS practice guidelines for the care of patients with an abdominal aortic aneurysm: executive summary. J Vasc Surg. 2009,50:880-96. [ Links ]

8. Rosen R, Green R. Endoleak management following endovascular aneurysm repair. J Vasc Interv Radiol. 2008;19:37-43. [ Links ]

9. Schwarze M, Shen Y, Hemmerich J, Dale W. Age-related trends in utilization and outcome of open and endovascular repair for abdominal aortic aneurysm in the United States, 2001-2006. J Vasc Surg. 2009;50:722-9. [ Links ]

10. Katsargyris A, Yazar O, Oikonomou K, Bekkema F, Tielliu I, Verhoeven E. Fenestrated stent-grafts for salvage of prior endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2013;46:49-56 [ Links ]

11. Doumenc B, Mesnard T, Patterson B, Azzaoui R, Préville A, Haulon S et al. Management of Type IA Endoleak After EVAR by Explantation or Custom Made Fenestrated Endovascular Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg 2021;61:571-8. [ Links ]

12. Verhoeven E, Muhs B, Zeebregts C, Tielliu I, Prins T, Bos W et al. Fenestrated and branched stent-grafting after previous surgery provides a good alternative to open redo surgery. Eur J Vasc Endovasc Surg 2007;33:84-90. [ Links ]

13. Wang S, Drucker N, Sawchuk A, Lemmon G, Dalsing M, Motaganahalli R et al. Use of the Zenith fenestrated platform to rescue failing endovascular and open aortic reconstructions is safe and technically feasible. J Vasc Surg. 2018;68:1017-22. [ Links ]

14. Kasprzak P, Pfister K, Kuczmik W, Schierling W, Sachsamanis G, Oikonomou K. Novel Technique for the Treatment of Type Ia Endoleak After Endovascular Abdominal Aortic Aneurysm Repair. J Endovasc Ther. 2021;4:519-23. [ Links ]

15. Paludetto G, Meulen S, Ouriel K, Patarca R. Physician Modified Low Profile Endograft for Endovascular Repair of Juxtarenal Abdominal Aortic Aneurysms in Patients with Small Access Vessels. EJVES Vasc Forum. 2021;51:9-12 [ Links ]

16. Starnes BW. Physician-modified endovascular grafts for the treatment of elective, symptomatic, or ruptured juxtarenal aortic aneurysms. J Vasc Surg. 2012;56:601-7 [ Links ]

Received: July 28, 2021; Revised: April 09, 2022; Accepted: July 27, 2022

Corresponding Author: Fábio Pais | fabioflpais@hotmail.com Angiology and Vascular Surgery Department, Hospital de Santa Marta, Centro Hospitalar Universitário Lisboa Central. Rua de Santa Marta 50, Piso 3, 1169-024, Lisbon, Portugal

Creative Commons License This is an open-access article distributed under the terms of the Creative Commons Attribution License