SciELO - Scientific Electronic Library Online

 
vol.20 número1-2Influence of graphite nodules on fatigue limit of nodular cast ironStructural details in lightweight aluminium crafts: Ways of improving structural reliability by applying “safe life” vs. “fail safe” principles índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Ciência & Tecnologia dos Materiais

versión impresa ISSN 0870-8312

Resumen

FERRAZ, M. Teresa  y  OLIVEIRA, Manuela. Steel fasteners failure by hydrogen embrittlement. C.Tecn. Mat. [online]. 2008, vol.20, n.1-2, pp.128-133. ISSN 0870-8312.

This paper details the analysis carried out on two failed bolts to find out the reason for failure, using macrofractography, optical metallography and scanning electron microscope (SEM) techniques. Usual measures to prevent such failures are also referred. Similar fractures occurred at the head to shank transition of the bolts during fastening, or afterwards, while waiting for delivery. Since failure occurred in a region where foreseen stresses were quite below yield strength and there was no evidence of mechanical deformation, embrittlement was suspected. SEM observation of the fracture surface crack initiation region showed areas of intergranular crack propagation indicating brittleness, and higher magnification observation showed hydrogen embrittlement features. The bolts, which microstructure was typically that of hardened and tempered steel, had been zinc electroplated and it is well known that hydrogen release concurs with zinc deposition. Moreover, the diffusion and accumulation of the hydrogen in metals is favoured by cold working, as is the case of the head to shank transition region.

Palabras clave : Hydrogen embrittlement; failure; steel; fractography; scanning electron microscopy.