GUAUS, E.    TORRENT-BURGUES, J.. Electrochemical Response of a Vitreous Carbon Electrode Modified by a Thiomacrocyclic Compound Film. []. , 25, 1, pp.139-152. ISSN 0872-1904.

A Langmuir-Schaefer (LS) film of a thiomacrocyclic (ThM) compound was deposited on the surface of a glassy carbon electrode (GCE) rod, from a subphase containing Cu(II) ions. The voltammetric response of this modified GCE when the ThM was bonded to Cu2+, showed that the LS film moved the oxidation peaks of copper to more positive values. On the other hand, a LS film of the ThM compound was deposited on the surface of a GCE rod from a subphase of pure water. When the voltammetric response of the GCE-ThM electrode was studied in a Cu2+-SO42- solution, it was found that the modified electrode increases its sensitivity respect to Cu2+ at low bulk Cu2+ concentrations in solution, and a surface-complexation reaction is proposed to explain the effect of the LS film on the GCE surface.

: modified electrodes; Langmuir-Schaefer films; cyclic voltammetry; surface-complexation reaction.