Servicios Personalizados
Revista
Articulo
Indicadores
- Citado por SciELO
- Accesos
Links relacionados
- Similares en SciELO
Compartir
Portugaliae Electrochimica Acta
versión impresa ISSN 0872-1904
Resumen
REYNA, S.L. Rodríguez et al. State of Corrosion of Rebars Embedded in Mortar Specimens After an Electrochemical Chloride Removal. Port. Electrochim. Acta [online]. 2010, vol.28, n.3, pp.153-164. ISSN 0872-1904.
This work attempts to determine the best conditions for applying the Electrochemical Chloride Removal (ECR) in rebars embedded in cement mortar with chloride additions by monitoring the corrosion rates before, during and after the application of an ECR. The ECR was applied at different conditions of current density (1 and 2 A/m2 of steel surface), application times (15, 30 and 60 days) and degree of precorrosion of the rebars. According to the results obtained, if ECR is applied preventively, it is an efficient procedure for delaying the start of corrosion. However, if applied too late, it does not assure the repassivation of corroded reinforced concrete structures and is therefore useless. The efficiency of the ECR depends heavily on the application time and the degree of precorrosion of the rebars.
Palabras clave : electrochemical chloride removal; rebars; electrochemical techniques; corrosion; mortar.