SciELO - Scientific Electronic Library Online

 
vol.21 número1Doença de Scheuermann: Fixação transpedicular e osteotomias apicais no tratamento exclusivo por via posteriorLigamentoplastia do ligamento cruzado anterior Do osso-tendão-osso para os isquiotibiais: melhorámos? índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Portuguesa de Ortopedia e Traumatologia

versión impresa ISSN 1646-2122

Resumen

CAMACHO, António et al. Resultados da utilização de implantes de tântalo poroso em cirurgia de revisão acetabular. Rev. Port. Ortop. Traum. [online]. 2013, vol.21, n.1, pp.17-25. ISSN 1646-2122.

The acetabular bone defects increase the complexity of the hip revision surgery by limiting the position of the acetabular components. Also, they may decrease the host bone contact área, compromising the primary stability of the implant. There is a growing body of information that suggests the usefulness of porous tantalum implants in situations where there is an acetabular bone defect, since this material has characteristics that increase primary stability and enhance osteointegration. The primary objective of this work is to evaluate, using standardized radiographic measures and validated clinical scores, a series of patients submitted to a revision hip surgery using porous tantalum implants. Between November 2005 and March 2011, 27 revision hip surgeries were performed by a single surgeon, (PD), using the porous tantalum implants. Twenty two percent (6 cases) were type IIIa of the Paprosky acetabular classification, and 4% (1 case) type IIIb. Mean follow up was 32 months. In the radiographic evaluation we found that in all the cases the center of rotation was moved to a more favorable position after the surgery. There was no implant loosening during the follow up. The Harris Hip Score went from a preoperative mean of 29,1 (min 2,8 - max 81,8) to a mean of 77,9 (min 33 - max 100) at the latest follow up visit (p<0,001). In this series of selected patients, the use of porous tantalum implants, pre-operative planning and meticulous surgical technique led to a good clinical and radiological result that was maintained during follow up.

Palabras clave : Hip; acetabulum; prosthesis; prosthesis failure; adult; Human; treatment outcome; arthroplasty.

        · resumen en Portugués     · texto en Portugués     · Portugués ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons