SciELO - Scientific Electronic Library Online

 
vol.40 issue5Heat-treatment (Annealing) Effect on the Mechanical and Electrochemical Performance of a Synthesized AlCrFeMnNiV Equi-atomic High Entropy Alloy (HEA) via Arc-melting and Casting Technologies author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • Have no similar articlesSimilars in SciELO

Share


Portugaliae Electrochimica Acta

Print version ISSN 0872-1904

Port. Electrochim. Acta vol.40 no.5 Coimbra Oct. 2022  Epub Aug 31, 2022

https://doi.org/10.4152/pea.2022400501 

Research Article

Development of 2-aminobenzoic Acid as a Complexing Ligand for Simultaneous Adsorptive Cathodic Stripping Voltammetric Determination of Trace Copper, Lead and Cadmium

E. Zarei1 

A. Izadyar2 

A. Asghari2 

M. Rajabi2 

1Department of Basic Sciences, Farhangian University, Tehran, Iran

2Department of Chemistry, Faculty of Sciences, Semnan University, Semnan, Iran


Abstract

In this study, 2-aminobenzoic acid (ABA) has been used as a complexing ligand for metal ions simultaneous determination by adsorptive cathodic stripping voltammetry (AdCSV). This selective and sensitive method was based on Cu(II), Pb(II) and Cd(II) ions + ABA adsorptive accumulation, by hanging them onto a mercury drop electrode (HMDE), followed by their reduction through differential pulse cathodic stripping voltammetry (DPSCV). Experimental parameters, such as pH, ABA concentration, accumulation time, potential and scan rate, were examined. Under the optimized conditions, linear calibration curves were established for Cu, Pb and Cd concentrations, in the ranges from 5 to 120, 5 to 150 and 5 to 120 ng/mL-1, respectively. Detection limits (LODs) of 2.05, 1.78 and 2.26 ng/mL-1 were obtained for Cu, Pb and Cd, respectively. The proposed method was applied for the determination of these elements in tap and industrial waste water, as real samples.

Keywords: copper; lead; cadmium; 2-aminobenzoic acid; AdCSV; water samples

Introduction

Pollution by heavy metals, such as Cu, Pb and Cd, is one of the most serious environmental problems 1. They are highly toxic to both humans and animals, including their nervous, immune, reproductive, and gastrointestinal systems 2), (3. Sensitive methods for Cu, Pb and Cd trace amounts determination have received much attention, and many techniques have been employed to develop them. Flame atomic absorption spectrometry (FAAS), graphite furnace atomic absorption spectrometry (GFAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES) are widely used analytical techniques for Pb 4), (5, Cu 4), (6)-(9 and Cd 4)-(6), (10)-(14 detection. Anodic stripping voltammetry (ASV) and AdCSV techniques have shown numerous advantages, including speed of analysis, good selectivity, sensitivity and performance with different matrices 15), (16. ASV application to samples with complex matrices is limited, due to the interfering components adsorption onto the electrode surface and, consequently, the loss of electrode activity, and irreproducible results. Also, Cu determination by ASV is not very sensitive, due to the broadness and closeness of the metal anodic peak potential to that of mercury (Hg) oxidation 17. The main problem with Cu and other heavy metals simultaneous determination by ASV is the formation of intermetallic compounds between this metal and others, especially Cu-Cd and Cu-Zn compounds 18. Generally, when Cu is present at concentrations higher than those of the ion of interest, the stripping peak of the latter is severely suppressed or is shifted to another potential.

AdCSV is an alternative method to determine trace metals 19), (20. This technique is based on the adsorptive accumulation of metal complexes with an added ligand onto the electrode, followed by the adsorbed complexes electrochemical reduction (15). Several chelating reagents, such as oxine 21, 1-(2-pyridylazo)-2,7-dihydroxy naphthalene 22 and thymolphthalexone 23, were used for Cd determination. Also, several ligands, such as 2-[2,3,5-triazolylazo]-5-dimethyl-aninobenzonic 24, salicylaldehyde thiosemicarbazone 25, cyclopentanone thiosemicarbazone 26, morin 27, oxine 28, 5,5-dimethylcyclohexane-1,2,3-trione 1,2-dioxime 3-thiosemicarbazone 29 and α-benzylmonooxime 30, were already applied for Cu and organic compounds determination (eg. morin) 27. A mixture of dimethylglyoxime and oxine 31, and carbidopa 32, as complexing agents, was reported for Pb voltammetric determination. AdCSV was successfully used for heavy metals individual and simultaneous determination. In previous works, this method for Ni-Cu 33, Pb-Zn 34, Cd-Cu 35), (36, Pb-Cu 23), (27 and Pb-Cu-Cd 37)-(39 determination, with different ligands, was described.

That we know, there is no report about the application of 2-aminobenzoic acid (ABA) as a ligand in metal ions determination using AdCSV technique. Therefore, in this work, an AdCSV procedure for Cd(II), Pb(II) and Cu(II) simultaneous determination, with ABA as a complexing agent, was described. Also, various factors influencing the method were investigated. This method was used for Cd(II), Pb(II) and Cu(II) ions determination in tap and industrial waste water samples.

Experimental details

Apparatus

A Metrohm 746/747 VA processor, with a three-electrode cell, made of HMDE, Ag/AgCl (saturated KCl), and platinum, as working, reference and counter electrodes, respectively, was used in differential pulse voltammetry (DPV). All reported potentials were referred to the WE. DPV had a pulse amplitude of 50 mV. The pH measurements were performed by a Metrohm 691 pH meter, with a combined glass electrode. A Varian AA-50 atomic absorption spectrometer, equipped with Pb and Zn hollow cathode lamps, was used for AB measurements.

Chemicals

All solutions were prepared with doubly distilled water. The stock solutions of 1000 mg/L-1 Cu(II), Pb(II) and Cd(II) were prepared by carefully weighting solid Cu nitrate (NO3-), Pb NO3- and Cd NO3- (Merck), and dissolving them in aqueous 0.5 mol L-1 nitric acid (HNO3). ABA (Merck) solution was prepared by dissolving an appropriate amount of it in 96% ethanol, and diluting it with doubly distilled water, in different 100 mL volumetric flasks.

Procedures

The supporting electrolyte solution (phosphate buffer (PB), with pH 7.4) was transferred into the electrochemical cell and purged with nitrogen (N) for, at least, 4 min. The accumulation potential (0.0 V vs. 3 M Ag/AgCl/KCl) was applied to a fresh Hg drop, while the solution was stirred for a period of 10 s of accumulation time. Then, after equilibration for 10 s, voltammograms were recorded from 0.35 to -0.76 V, with a potential scan rate of 10 mV/s-1 and a pulse amplitude of 50 mV. Afterwards, Cu, Pb and Cd standard solutions aliquots were introduced into the cell, and the obtained solution was deoxygenated with N gas, for 1 min. Then, a DPV was recorded, according to the described procedure, to give the sample peak current. Each scan was repeated five times, with a new drop for each analyzed solution, and the mean value was obtained. Cu, Pb and Cd stripping peaks were registered at about 0.094, -0.319 and -0.520 V, respectively, and their currents were used as the method for measuring the magnitude of their analytical signals. All data were obtained at room temperature. Calibration graphs were prepared taking the peak current against Cu(II), Pb(II) and Cd(II) concentrations.

Results and discussion

Preliminary experiments were carried out using DP-AdCSV to identify the general features that characterized the Cu(II)-ABA, Pb(II)-ABA and Cd(II)-ABA systems behavior on HMDE. Fig. 1a displays DPVs of the PB (pH 7.0) on the HMDE surface, with a scan rate of 10 mV/s-1.

Figure 1 DP-AdCS voltammograms of: a) blank solution (PB with pH 7.0); b) blank solution with 70 ng/mL-1 of each of Cu(II), Pb(II) and Cd(II); and c) metal ions + 0.40 mM ABA ligand, on the HMDE surface, at an accumulation potential of -0.25 V, accumulation time of 60 s and a scan rate of 10 mV/s-1

Effect of pH solution

The pH effect on the cathodic stripping peaks current of Cu, Ni, Cd and Pb was studied in the pH range from 6 to 8, in a solution containing 70 ng/mL-1 of Cu(II), Pb(II) and Cd(II), with 0.45 mmol/L-1 ABA, recording DP-AdCS voltammograms onto the HMDE, by adsorptive accumulation, at -0.25 V, for 60 s. Fig. 2 shows the dependence of the peak heights on the pH. As it is seen, the metal ions peak height increased in the pH range from 6 to 7.4, and decreased at pH values higher than 7.4 and lower than 6.5. That may be due to the metal ions hydroxocomplex formation and ABA protonation, respectively. In spite of this, the maximum peaks currents were obtained at pH 7.4, for both metal ions that were selected for subsequent experiments.

Figure 2 DP-AdCS voltammetric peak current as a function of pH on the HMDE surface, for a solution with 70 ng/mL-1 of Cu(II), Pb(II) and Cd(II) + 0.40 mM ABA, at an accumulation potential of -0.25 V, accumulation time of 60 s and scan rate of 10 mV/s-1

Ligand concentration effect

The dependence of the Cu(II)-ABA, Pb(II)-ABA and Cd(II)-ABA peaks current on the complexing agent concentration was tested. DP-AdCS voltammograms of 70 ng/mL-1 Cu(II), Cd(II) and Pb(II) + increased amounts of ABA (0.2-5.3 mM) were recorded in an aqueous PB with pH 7.4, following the preconcentration of these metal ions + ABA complexes onto the HMDE, at -0.25 V, by adsorptive accumulation, for 60 s. The obtained results (Fig. 3) showed that the Cu(II)-ABA, Pb(II)-ABA and Cd(II)-ABA complexes peaks currents increased along with higher ligand concentrations, up to 0.45 mM.

Figure 3 Effect of the ligand concentrations on the determination of 70 ng/mL-1 Cu(II), Pb(II) and Cd(II), with pH of 7.4, accumulation potential of -0.25 V, accumulation time of 60 s and scan rate of 10 Mv/s-1

Beyond this concentration, the peak height gradually decreased, probably due to some competition between the complexes and the ligand for the adsorption onto the electrode surface. Consequently, an optimum ABA concentration of 0.45 mM was selected for further experiments.

Accumulation parameters effect

The charge on the Hg electrode surface plays an important role in the metal complexes absorption efficiency 40. In its turn, the solution applied potential and composition significantly affects the charge on the Hg electrode. Therefore, in this study, the accumulation potential effect on the stripping peaks current of metal ions + ABA complexes was individually examined, over the potential range from ‏0.15 to -0.40 V. The stripping peaks current plots of both metal ions, as a function of the preconcentration potential, are shown in Fig. 4A. As it is obvious, the peaks current increased up to about -0.2 for all metal ions, and slightly decreased towards more negative values. This behavior is due to a competition between the complexes and the ligand for the adsorption onto the electrode surface. Subsequently, the accumulation potential of -0.2 V was used in all further DP-AdCSV measurements.

Figure 4 The influence of: A) accumulation potential; B) accumulation time; and C) scan rate on the cathodic adsorption stripping peak current of 70/ng mL-1 of Cu(II), Pb(II) and Cd(II), in a PB with pH 7.4, + 0.45 mM ABA. Other conditions: A) accumulation time of 60 s and scan rate of 10 Mv/s-1; B) accumulation potential of -0.2 V and scan rate of 10 Mv/s-1; and C) accumulation potential of -0.2 V and accumulation time of 65 s. 

On the other hand, DP-AdCS voltammograms of 70 ng/mL-1 of Cu(II), Pb (II) and Cd(II), in a PB, + 0.45 mM ABA, were recorded under optimum conditions, following an increased preconcentration time (30-120 s), by adsorptive accumulation, at -0.2 V. As shown in Fig. 4B, the peak current of all metal ions-ABA complexes increased with the accumulation time. At higher ion concentrations, the adsorptive saturation of the Hg electrode surface (adsorption equilibrium) was reached and, hence, the peak current levelled off. Therefore, an accumulation time of 65 s was selected for further studies. The scan rate effect was also tested in the range from 2 to 30 Mv/s-1 (Fig. 4C). The current (metal ions-ABA) was found constant, at a scan rate higher than 10 Mv/s-1, which was selected for Cu(II), Pb(II) and Cd(II) simultaneous determination.

Cu(II), Cd(II) and Pb(II) simultaneous determination

DP-AdCS voltammograms of the metal ions, at various concentrations, were recorded under optimum procedural conditions (Fig. 5).

Figure 5 HDME DP-AdCS voltammograms with Cu(II), Pb(II) and Cd(II) various concentrations: 0, 5, 20, 50, 60, 70 and 80 ppm, in a PB with pH 7.4, + 0.45 mM ABA, after preconcentration at -0.2 V onto the HMDE, by adsorptive accumulation, for 65 s, at a scan rate of 10 Mv/s-1

Rectilinear relations between the peak current (Ip) and Cu(II), Pb(II) and Cd(II) concentrations were obtained over the ranges indicated in Table 1. The results confirm the described DP-AdCS voltammetry method reliability for the Cu(II), Pb(II) and Cd(II) simultaneous determination, within the indicated linear ranges.

Table 1 Characteristics of the calibration curves of the described DP-AdCS voltammetric method for the Cu(II), Pb(II) and Cd(II) + ABA simultaneous determination, under optimum conditions. 

Interference studies

In multi-elemental determinations at the Hg electrode, the effect of the interference between metal ions is potentially important, because they compete for complexation with the same ligand, and for adsorption onto the Hg drop. Moreover, the inter-metallic compounds formation among the investigated metal ions may cause an error in their determination. Possible interference by other metal ions on the Cu(II), Pb(II) and Cd(II) AdCSV was investigated through the addition of the interfering ion to a solution containing these metals, under optimized conditions. The results of this study are summarized in Table 2. The tolerance limit was defined as the concentration that gave an error of 3% in Cu(II), Pb(II) and Cd(II) determination. Based on the results, it was concluded that the method is almost free from the interference of the foreign ions. However, a 1-fold concentration of Al(III) (aluminum) had a significant influence on Cu(II), Pb(II) and Cd(II) determination, and 2-fold concentrations of Fe(II) (iron) had a major interference in Cu(II) determination. Interference from Al(III) and Fe(II) ions can be minimized by the addition of 400 and 500-fold concentrations of F- (fluorine) and SCN- ions (thiocyanate), respectively, if necessary.

Table 2 The effect of foreign ions on the determination of 70 ng/mL-1 of each metal ion, under optimum conditions. 

[a] After addition of 400-fold concentrations of F- ions to the solution; [b] After addition of 500-fold concentrations of SCN- ions to the solution

Tap water and waste water samples analysis

The described DP-AdCS voltammetry method was successfully applied for Cu(II), Pb(II) and Cd(II) simultaneous determination, in a sample of tap water from Semnan, and in industrial waste water samples from alloys producer companies (Table 3).

Table 3 Cu(II), Cd(II) and Pb(II) determination in tap and industrial waste water samples, by the DP-AdCS voltammetry method, under optimum conditions, and by FAAS. 

[a] Concentrated by 25-fold. [b] Not found, but added 20 ppm and they were found 19.80 ppm, with a recovery percentage of 99.0%

The same water samples were also analyzed for these metal ions determination by FAAS. A comparison of the results obtained by the DP-AdCS voltammetry method with those resulting from FAAS revealed the capability of the stripping voltammetry method for Cu(II), Pb(II) and Cd(II) determination, at trace concentrations. The results correspond to the mean values of five replicate determinations.

Conclusions

A selective and sensitive DP-AdCSV method was developed for Cu(II), Pb(II) and Cd(II) simultaneous determination, as 2-aminobenzoic acid-complexes in water samples, without significant interference from foreign cations and anions, for the first time. The proposed method presented LODs of ng/mL-1 levels for Cu(II), Pb(II) and Cd(II) determination. The method was successfully applied for these metal ions determination in tap water and industrial waste water samples.

Authors’ contributions

E. Zarei: conceived and designed the analysis, contributed with data or analysis tools, performed the analysis and wrote the paper. A. Izadyar: conceived and designed the analysis, collected the data, contributed with data or analysis tools and performed the analysis. A. Asghari: conceived and designed the analysis, contributed with data or analysis tools and performed the analysis. M. Rajabi: other contributions.

References

1. Runnells DD, Shepherd TA, Angino EE. Metals in water. Determining natural background concentrations in mineralized areas. Environ Sci Technol, 1992;26:2316-2323. DOI: https://doi.org/10.1021/es00036a001 [ Links ]

2. Kemper T, Sommer S. Estimate of heavy metal contamination in soils after a mining accident using reflectance spectroscopy. Environ Sci Technol. 2002;36:2742-2747. DOI: https://doi.org/10.1021/es015747j [ Links ]

3. Jang A, Seo YW, Bishop PL. The removal of heavy metals in urban run off by sorption on mulch. Environ Pollut. 2005;133:117-127. DOI: https://doi.org/10.1016/j.envpol.2004.05.020 [ Links ]

4. Tu Y, Ju S, Wang P. Flame atomic absorption spectrometric determination of copper, lead, and cadmium in Gastrodiae rhizoma samples after preconcentration using magnetic solid-phase extraction. Spectrosc Lett. 2016;49:249-256. DOI: https://doi.org/10.1080/00387010.2015.1134578 [ Links ]

5. Wei XS, Wu YW, Han LJ. Determination of lead and cadmium in water and pharmaceutical products by inductively coupled plasma optical emission spectrometry with preconcentration by thiourea immobilized silica. Analyt Lett. 2015;48:996-1008. DOI: https://doi.org/10.1080/00032719.2014.966379 [ Links ]

6. Sabermahani F, Taher MA. Determination of trace amounts of cadmium and copper by atomic absorption spectrometry after simultaneous extraction and preconcentration using a new water-soluble polyacrylic acid/alumina sorbent. Microchim Acta. 2007;159:117-123. DOI: https://doi.org/10.1007/s00604-006-0729-0 [ Links ]

7. Zacharia A, Gucer S, Izgi B, et al. Direct atomic absorption spectrometry determination of tin, lead, cadmium and zinc in high-purity graphite with flame furnace atomizer. Talanta. 2007;72:825-830. DOI: https://doi.org/10.1016/j.talanta.2006.10.040 [ Links ]

8. Yawar W. Determination of wear metals in lubricating oils by flame atomic absorption spectrophotometry. J Anal Chem. 2010;65:489-491. DOI: https://doi.org/10.1134/S1061934810050096 [ Links ]

9. Jahromi EZ, Bidari A, Assadi Y, et al. Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry: Ultra trace determination of cadmium in water samples. Analyt Chim Acta. 2007;585:305-311. DOI: https://doi.org/10.1016/j.aca.2007.01.007 [ Links ]

10. Filatova DG, Es'kina VV, Chizhov AS, et al. Determination of selenium and cadmium dopants in nanocomposites based on zinc and indium oxides by high resolution continuous source electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry. J Analyt Chem. 2016;71:496-499. DOI: https://doi.org/10.1134/S106193481605004X [ Links ]

11. Ghaedi M, Ahmadi F, Shokrollahi A. Simultaneous preconcentration and determination of copper, nickel, cobalt and lead ions content by flame atomic absorption spectrometry. J Hazar Mater. 2007;142:272-278. DOI: https://doi.org/10.1016/j.jhazmat.2006.08.012 [ Links ]

12. Minami T, Sohrin Y, Ueda J. Determination of chromium, copper and lead in river water by graphite-furnace atomic absorption spectrometry after coprecipitation with terbium hydroxide. Analyt Sci. 2005;21:1519-1521. DOI: https://doi.org/10.2116/analsci.21.1519 [ Links ]

13. Zeiner M, Steffan I, Cindric IJ. Determination of trace elements in olive oil by ICP-AES and ETA-AAS: A pilot study on the geographical characterization. Microchem J. 2005;81:171-176. DOI: https://doi.org/10.1016/j.microc.2004.12.002 [ Links ]

14. Karadjova I, Izgi B, Gucer S. Fractionation and speciation of Cu, Zn and Fe in wine samples by atomic absorption spectrometry. Spectrochim Acta B. 2002;57:581-590. DOI: https://doi.org/10.1016/S0584-8547(01)00386-X [ Links ]

15. Wang J. Analytical electrochemistry, 2nd edn. Wiley-VCH, New York, 2001. [ Links ]

16. Benabbes M, Alami Chentoufi Mojemmi B, et al. Determination of lead and cadmium in synthetic and natural hair dyes in Morocco using differential pulse polarography. Port Electrochim Acta. 2021;39:37-44. DOI: https://doi.org/10.4152/pea.202101037 [ Links ]

17. Hajian R, Shams E. Application of adsorptive stripping voltammetry to the determination of bismuth and copper in the presence of morin. Analyt Chim Acta. 2003;491:63-69. DOI: https://doi.org/10.1016/S0003-2670(03)00789-X [ Links ]

18. Wang J. Stripping analysis: Principles, instrumentation and applications, VCH, Deerfield Beach, FL, 1985. [ Links ]

19. Grabarczyk M, Koper A. Simultaneous voltammetric determination of Mo(VI) and W(VI) by adsorptive differential pulse stripping method using adaptive neuro-fuzzy inference system. J Analyt Chem. 2013;68:885-890. DOI: https://doi.org/10.1134/S1061934813100134 [ Links ]

20. Ghandour MA, Hassan A, Ali HM. Voltammetric determination of copper with proton pump inhibitor drug omeprazole. J Analyt Chem. 2015;70:392-397. DOI: https://doi.org/10.1134/S1061934815030065 [ Links ]

21. El-Desoky HS, Ismail IM, Ghoneim MM. Stripping voltammetry method for the determination of manganese as complex with oxine at the carbon paste electrode with and without modification with montmorillonite clay. J Solid State Electrochem. 2013;17:3153-3167. DOI: https://doi.org/10.1007/s10008-013-2204-2 [ Links ]

22. Zhang ZQ, Chen SZ, Lin HM, et al. Simultaneous determination of copper, nickel, lead, cobalt and cadmium by adsorptive voltammetry. Analyt Chim Acta. 1993;272:227-232. DOI: https://doi.org/10.1016/0003-2670(93)80573-4 [ Links ]

23. Babaei A, Shams E, Samadzadeh A. Simultaneous determination of copper, bismuth and lead by adsorptive stripping voltammetry in the presence of thymolphthalexone. Analyt Sci. 2006;22:955-959. DOI: https://doi.org/10.2116/analsci.22.955 [ Links ]

24. Lu G, Long D, Li D, et al. Determination of copper in food by stripping voltammetry using Cu(II)-[2-(2, 3, 5-triazolylazo)-5-dimethylaninobenzonic] complex. Food Chem. 2004;84:319-322. DOI: https://doi.org/10.1016/S0308-8146(03)00261-9 [ Links ]

25. Mahajan RK, Walia TPS, Sumanjit LTS. The versatility of salicylaldehyde thiosemicarbazone in the determination of copper in blood using adsorptive stripping voltammetry. Talanta. 2005;67:755-759. DOI: https://doi.org/10.1016/j.talanta.2005.03.024 [ Links ]

26. Mahajan RK, Walia TPS, Sumanjit LTS. Cyclopentanone thiosemicarbazone, a new complexing agent for copper determination in biological samples by adsorptive stripping voltammetry. Analyt Sci. 2006;22:389-392. DOI: https://doi.org/10.2116/analsci.22.389 [ Links ]

27. Shams E, Babaei A, Soltaninezhad M. Simultaneous determination of copper, zinc and lead by adsorptive stripping voltammetry in the presence of morin. Analyt Chim Acta. 2004;501:119-124. DOI: https://doi.org/10.1016/j.aca.2003.09.010 [ Links ]

28. Van der Berg CMG. Determination of copper, cadmium and lead in seawater by cathodic stripping voltammetry of complexes with 8-hydroxyquinoline. J Electroanalyt Chem. 1986;215:111-121. DOI: https://doi.org/10.1016/0022-0728(86)87009-7 [ Links ]

29. Galeano DNaz T, Guiberteau A, Lopez Soto MD, et al. Determination of copper with 5, 5-dimethylcyclohexane-1, 2, 3-trione 1, 2-dioxime 3-thiosemicarbazone in olive oils by adsorptive stripping square wave voltammetry. Food Chem. 2006;96:156-162. DOI: https://doi.org/10.1016/j.foodchem.2005.04.014 [ Links ]

30. Ensafi AA, Abbasi S. Highly selective-cathodic stripping voltammetric determination of copper with a-benzylmonooxime. Microchem J. 2000;64:195-200. DOI: https://doi.org/10.1016/S0026-265X(00)00004-7 [ Links ]

31. Colombo C, van den Berg CMG. Simultaneous determination of several trace metals in seawater using cathodic stripping voltammetry with mixed ligands. Analyt Chim Acta. 1997;337:29-40. DOI: https://doi.org/10.1016/S0003-2670(96)00401-1 [ Links ]

32. Gholivand MB, Ahmadi F, Sohrabi A. Adsorptive stripping voltammetric determination of ultra-trace of zinc and lead with carbidopa as complexing agent in food and water samples. Electroanalysis. 2007;19:2465-2471. DOI: https://doi.org/10.1002/elan.200704007 [ Links ]

33. Cobelo-Garc A, Santos-Echeand J, Prego R, et al. Direct simultaneous determination of Cu, Ni and V in seawater using adsorptive cathodic stripping voltammetry with mixed ligands. Electroanalysis. 2005;17:906-911. DOI: https://doi.org/10.1002/elan.200403203 [ Links ]

34. Pardi H, Edelwis TW, et al. Differential pulse adsorptive cathodic stripping voltammetry for the simultaneous determination of Pb and Zn in seawater using calcon. Port Electrochim Acta. 2021;39:45-47. DOI: https://doi.org/10.4152/pea.202101045 [ Links ]

35. Babaei A, Babazadeh M, Shams E. Simultaneous determination of iron, copper, and cadmium by adsorptive stripping voltammetry in the presence of thymolphthalexone. Electroanalysis. 2007;19:978-985. DOI: https://doi.org/10.1002/elan.200603812 [ Links ]

36. Beltagi AM, Ghoneim MM. Simultaneous determination of trace aluminum (III), copper (II) and cadmium (II) in water samples by square-wave adsorptive cathodic stripping voltammetry in the presence of oxine. J Appl Electrochem. 2009;39:627-636. DOI: https://doi.org/10.1007/s10800-008-9703-3 [ Links ]

37. Collado-Sanchez C, Perez-Pena J, Gelado-Caballero MD, et al. Rapid determination of copper, lead and cadmium in unpurged seawater by adsorptive stripping voltammetry. Analyt Chim Acta. 1996;320:19-30. DOI: https://doi.org/10.1016/0003-2670(95)00513-7 [ Links ]

38. Ensafi AA, Khayamian T, Benvidi A, et al. Simultaneous determination of copper, lead and cadmium by cathodic adsorptive stripping voltammetry using artificial neural network. Analyt Chim Acta. 2006;561:225-232. DOI: https://doi.org/10.1016/j.aca.2006.01.015 [ Links ]

39. Deswati D, Suyani H, Umiati Loekman S, et al. Simultaneous determination of cadmium, copper and lead in sea water by adsorptive stripping voltammetry in the presence of calcon as a complexing agent. Indon J Chem. 2013;13:236-241. DOI: https://doi.org/10.22146/ijc.21282 [ Links ]

40. Vydra F, Stulik K, Julakoua E. Electrochemical Stripping Analysis. Wiley, US: New York, 1976. [ Links ]

Received: May 27, 2021; Accepted: October 20, 2021

Corresponding author: e.zarei@cfu.ac.ir

Creative Commons License This is an open-access article distributed under the terms of the Creative Commons Attribution License