<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0872-0169</journal-id>
<journal-title><![CDATA[Portuguese Journal of Nephrology & Hypertension]]></journal-title>
<abbrev-journal-title><![CDATA[Port J Nephrol Hypert]]></abbrev-journal-title>
<issn>0872-0169</issn>
<publisher>
<publisher-name><![CDATA[Sociedade Portuguesa de Nefrologia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0872-01692023000100017</article-id>
<article-id pub-id-type="doi">10.32932/pjnh.2023.02.230</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Sodium Citrate Versus Heparin Locking Solutions for Tunneled Hemodialysis Catheters]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Alves]]></surname>
<given-names><![CDATA[Patrícia]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Veríssimo]]></surname>
<given-names><![CDATA[Rita]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mendes]]></surname>
<given-names><![CDATA[Artur]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Davita Sacavém  ]]></institution>
<addr-line><![CDATA[Sacavém ]]></addr-line>
<country>Portugal</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2023</year>
</pub-date>
<volume>37</volume>
<numero>1</numero>
<fpage>17</fpage>
<lpage>20</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_arttext&amp;pid=S0872-01692023000100017&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_abstract&amp;pid=S0872-01692023000100017&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_pdf&amp;pid=S0872-01692023000100017&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT  Introduction:  Hemodialysis catheter dysfunction compromises dialysis adequacy and may limit catheter survival. Strategies to prevent hemodialysis catheter dysfunction include catheter locks, generally either with heparin or citrate.  Methods:  Our hemodialysis unit converted to locking all central venous hemodialysis catheters with sodium citrate 4% instead of heparina 5000 U/mL. A retrospective analysis compared the outcomes of the 6 months prior and after the conversion. The compared outcomes were incidence of catheter thrombosis, catheter-related infection, flow-related catheter exchange rate, dialysis efficiency measured by Kt/V and catheter dysfunction.  Results:  Twenty-three patients were included. Between the two audit periods, the rate of catheter thrombosis was 0 (0 per 1000 catheter days) and 7 (2.78 per 1000 catheter days) during the heparin and citrate period respectively (p=0.109). The number of catheter exchanges due to catheter dysfunction was 0 (0 per 1000 catheter days) during the heparin period and just 1 (0.39 per 1000 catheter days) during the citrate period (p=0.317). Dialysis adequacy measured by KT/V was 1.54 (0.39) in the heparin group and 1.54 (0.35) in the citrate group (p=0.465). Catheter dysfunction was recorded in 146 sessions (12.3%) in the heparin period and in 159 sessions (14,7%) in the citrate period (p=0.234). There were no catheter related infections in either group.  Conclusion:  There was a 58% cost reduction associated with catheter-locking therapy between the heparin period and the citrate period. This cost reduction included the costs associated with alteplase use. Besides the financial advantages in switching to citrate locking, there are other potential advantages, namely the minimization of heparin related side effects or limitations.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Catheter-Related Infections]]></kwd>
<kwd lng="en"><![CDATA[Catheterization, Central Venous]]></kwd>
<kwd lng="en"><![CDATA[Catheters, Indwelling]]></kwd>
<kwd lng="en"><![CDATA[Heparin]]></kwd>
<kwd lng="en"><![CDATA[Renal Dialysis]]></kwd>
<kwd lng="en"><![CDATA[Sodium Citrate]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lok]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Huber]]></surname>
<given-names><![CDATA[TS]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Shenoy]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Yevzlin]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Abreo]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[KDOQI clinical practice guideline for vascular access: 2019 update]]></article-title>
<source><![CDATA[Am J Kidney Dis]]></source>
<year>2020</year>
<volume>75</volume>
<page-range>S1-164</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weijmer]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Debets-Ossenkopp]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[van de Vondervoort]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[ter Wee]]></surname>
<given-names><![CDATA[PT]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Superior antimicrobial activity of trisodium citrate over heparin for catheter locking]]></article-title>
<source><![CDATA[Nephrol Dial Transplant]]></source>
<year>2002</year>
<volume>17</volume>
<page-range>2189-95</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gunawansa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Sudusinghe]]></surname>
<given-names><![CDATA[DH]]></given-names>
</name>
<name>
<surname><![CDATA[Wijayaratne]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Hemodialysis Catheter-Related Central Venous Thrombosis: Clinical Approach to Evaluation and Management]]></article-title>
<source><![CDATA[Ann Vasc Surg]]></source>
<year>2018</year>
<volume>51</volume>
<page-range>298-305</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moran]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Ash]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Locking solutions for hemodialysis catheters; Heparin and citrate - A position paper by ASDIN]]></article-title>
<source><![CDATA[Semin Dial]]></source>
<year>2008</year>
<volume>21</volume>
<page-range>490-2</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Citrate versus heparin lock for hemodialysis catheters: A systematic review and meta-analysis of randomized controlled trials]]></article-title>
<source><![CDATA[Am J Kidney Dis]]></source>
<year>2014</year>
<volume>63</volume>
<page-range>479-90</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pierce]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Rocco]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Trisodium citrate: An alternative to unfractionated heparin for hemodialysis catheter dwells]]></article-title>
<source><![CDATA[Pharmacotherapy]]></source>
<year>2010</year>
<volume>30</volume>
<page-range>1150-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mai]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zhao]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Salerno]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Feng]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Citrate versus heparin lock for prevention of hemodialysis catheter-related complications: updated systematic review and meta-analysis of randomized controlled trials]]></article-title>
<source><![CDATA[Int Urol Nephrol]]></source>
<year>2019</year>
<volume>51</volume>
<page-range>1019-33</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Portuguese Registry of Dialysis andTransplantation]]></article-title>
<source><![CDATA[Sociedade Portuguesa de Nefrologia]]></source>
<year>2020</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grudzinski]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Quinan]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kwok]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Pierratos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Sodium citrate 4% locking solution for central venous dialysis catheters - An effective, more cost-efficient alternative to heparin]]></article-title>
<source><![CDATA[Nephrol Dial Transplant]]></source>
<year>2007</year>
<volume>22</volume>
<page-range>471-6</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>