<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0872-1904</journal-id>
<journal-title><![CDATA[Portugaliae Electrochimica Acta]]></journal-title>
<abbrev-journal-title><![CDATA[Port. Electrochim. Acta]]></abbrev-journal-title>
<issn>0872-1904</issn>
<publisher>
<publisher-name><![CDATA[Sociedade Portuguesa de Electroquímica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0872-19042008000100006</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Preliminary Studies Towards the Development of DNA Biosensors for Detection of Cylindrospermopsin - A Cyanobacterial Toxin]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valério]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Tenreiro]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Abrantes]]></surname>
<given-names><![CDATA[L.M.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidade de Lisboa Faculdade de Ciências Centro de Química e Bioquímica]]></institution>
<addr-line><![CDATA[Lisboa ]]></addr-line>
<country>Portugal</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2008</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2008</year>
</pub-date>
<volume>26</volume>
<numero>1</numero>
<fpage>77</fpage>
<lpage>87</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_arttext&amp;pid=S0872-19042008000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_abstract&amp;pid=S0872-19042008000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_pdf&amp;pid=S0872-19042008000100006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[The suitability of polytyramine (PTy) modified electrodes for the development of DNA biosensors is analysed in this work. PTy films were synthesised potentiodynamically on Pt electrode, from acidic aqueous solution. A cylindrospermopsin coding sequence (PKSM4 probe 5’-phosphate modified) was covalently bound on the polytyramine matrix using N-hydroxysuccinimide (NHS) and 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC) as coupling agents. Changes of the open circuit potential were registered as a first approach to monitorise the immobilization and hybridization processes. The modified electrodes have been characterised by cyclic voltammetry and square wave voltammetry, using methylene blue (MB), as electroactive indicator and the successful immobilization and hybridization steps are revealed by the increase of the peak currents. The hybridization has also been confirmed by measuring the fluorescence of the modified electrodes after staining with PicoGreen® DNA dye.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[cylindrospermopsin]]></kwd>
<kwd lng="en"><![CDATA[DNA biosensor]]></kwd>
<kwd lng="en"><![CDATA[PicoGreen®]]></kwd>
<kwd lng="en"><![CDATA[polytyramine]]></kwd>
<kwd lng="en"><![CDATA[methylene blue]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="center"><b>Preliminary Studies Towards the Development of DNA Biosensors    for Detection of Cylindrospermopsin – A Cyanobacterial Toxin </b></p>     <p align="center">&nbsp;</p>     <p align="center">&nbsp;</p>     <p align="center"><b>E. Valério, A. Tenreiro and L.M. Abrantes<a href="#1">*</a><a name="top1"></a>    </b></p>     <p align="center">&nbsp;</p>     <p align="center"><i>Centro de Química e Bioquímica, Faculdade de Ciências, Universidade    de Lisboa, Campo Grande, </i></p>     <p align="center"><i>1749-016 Lisboa, Portugal</i></p>     <p align="center">&nbsp;</p>     <p align="center">Received 29<sup>th</sup> June 2007; accepted 3<sup>rd</sup>    October 2007</p>     <p align="center">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="center">&nbsp;</p>      <p><b>Abstract</b></p>      <p>The suitability of polytyramine (PTy) modified electrodes for the development of DNA biosensors is analysed in this work. PTy films were synthesised potentiodynamically on Pt electrode, from acidic aqueous solution. A cylindrospermopsin coding sequence (PKSM4 probe 5’-phosphate modified) was covalently bound on the polytyramine matrix using N-hydroxysuccinimide (NHS) and 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC) as coupling agents. Changes of the open circuit potential were registered as a first approach to monitorise the immobilization and hybridization processes. </p>      <p>The modified electrodes have been characterised by cyclic voltammetry and square wave voltammetry, using methylene blue (MB), as electroactive indicator and the successful immobilization and hybridization steps are revealed by the increase of the peak currents. The hybridization has also been confirmed by measuring the fluorescence of the modified electrodes after staining with PicoGreen<sup>®</sup> DNA dye.</p>      <p><b><i>Keywords: </i></b>cylindrospermopsin, DNA biosensor, PicoGreen<sup>®</sup>,    polytyramine, methylene blue.</p>     <p>&nbsp;</p>     <p>&nbsp;</p>      <p>Texto disponível em PDF</p>      <p>Full text only in PDF format</p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>      <p><b>References</b></p>      <!-- ref --><p>1.  F. Davis, S.P.J. Higson, <i>Biosens. Bioelec.</i> 21 (2005) 1–20.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000025&pid=S0872-1904200800010000600001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>2.  K. Kerman, M. Kobayashi, E. Tamiya, <i>Meas. Sci. Technol</i>. 15 (2004) R1-R11.</p>      <p>3.  M.A. Schembri, B.A. Neilan, C.P. Saint, <i>Environ. Toxicol.</i> 16 (2001) 413-421. </p>      <p>4.  K.M. Fergusson, C.P. Saint, <i>Environ. Toxicol.</i> 18 (2003) 120–125.</p>      <p>5.  D. Losic, M. Cole, H. Thissen, N.H. Voelcker, <i>Surf. Sci. </i>584 (2005) 245-257.</p>      <p>6.  L.D. Tran, B. Piro, M.C. Pham, T. Ledoan, C. Angiari, L.H. Dao, F. Teston, <i>Synth. Met</i>. 139 (2003) 251-262.</p>      <p>7.  A.M. Tenreiro, C. Nabais, J.P. Correia, F.M.S.S. Fernandes, J.R. Romero, L.M. Abrantes, <i>J. Solid State Electrochem.</i> (2006) DOI 10.1007/s10008-007-0268-6.</p>      <p>8.  S.A. Miscoria, G.D. Barrera, G.A. Rivas, <i>Sens. Actuators B</i> 115 (2006) 205-211.</p>      ]]></body>
<body><![CDATA[<p>9.  Y. Miao, J. Chen, Y. Hu, <i>Anal. Biochem.</i> 339 (2005) 41-45.</p>      <p>10.  E.V. Suprun, H.C. Budnikov, G.A. Evtugyn, Kh.Z. Brainina, <i>Bioelectrochem</i>. 63 (2004) 281-284.</p>      <p>11.  M. Situmorang, D.B. Hibbert, J.J. Gooding, D. Barnett, <i>Analyst</i> 124 (1999) 1775-1779.</p>      <p>12.  M. Situmorang, J.J. Gooding, D.B. Hibbert, <i>Anal. Chim. Acta</i> 394 (1999) 211-223.</p>      <p>13.  M. Situmorang, J.J. Gooding, D.B. Hibbert, D. Barnett, <i>Biosens. Bioelectron</i>. 13 (1998) 953-962.</p>      <p>14.  I. Tsuji, H. Eguchi, K. Yasukouchi, M. Unoki, I. Taniguchi, <i>Biosens. Bioelectron.</i> 5 (1990) 87-101.</p>      <p>15.  A.M. Tenreiro, C.M. Cordas, L.M. Abrantes, <i>Portugaliae Electrochim. Acta</i> 21 (2003) 361-370.</p>      <p>16.  C.M. Cordas, A.M. Tenreiro, L.M. Abrantes, <i>Nanostructured Materials and Coatings for Biomedical and Sensor Applications </i>(2003) 371-376.</p>      <p>17.  Z. Wu, J. Li, T. Deng, M. Luo, G. Shen, R. Yu, <i>Anal. Biochem.</i> 337 (2005) 308-315.</p>      <p>18.  M.I. Pividori, A. Merkoçi, S. Alegret, <i>Biosens. Bioelectron.</i> 15 (2000) 291-303.</p>      ]]></body>
<body><![CDATA[<p>19.  K. Kato, Y. Ikada, <i>Biotechnol. Bioeng.</i> 51 (1996) 581-590.</p>      <p>20.  D. Sehgal, I.K. Vijay, <i>Anal. Biochem.</i> 218 (1994) 87-91.</p>      <p>21.  M.J. Davies, A. Shah, I.J. Bruce, <i>Chem. Soc. Rev.</i> 29 (2000) 97-107.</p>      <p>22. A. Erdem, K. Kerman, B. Meric, M. Ozsoz, <i>Electroanalysis</i> 13 (2001)    219-223.</p>      <p>23. G. Xu, K. Jiao, J. Fan, W. Sun, <i>Acta Chim. Slov.</i> 53 (2006) 486-491.</p>     <p>&nbsp;</p>     <p>&nbsp;</p>       <p><a name="1"></a><a href="#top1">*</a> Corresponding authors. E-mail addresses:    <a href="mailto:luisa.abrantes@fc.ul.pt">luisa.abrantes@fc.ul.pt</a></p>           ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Davis]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Higson]]></surname>
<given-names><![CDATA[S.P.J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Biosens. Bioelec.]]></source>
<year>2005</year>
<volume>21</volume>
<page-range>1-20</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
