<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0872-1904</journal-id>
<journal-title><![CDATA[Portugaliae Electrochimica Acta]]></journal-title>
<abbrev-journal-title><![CDATA[Port. Electrochim. Acta]]></abbrev-journal-title>
<issn>0872-1904</issn>
<publisher>
<publisher-name><![CDATA[Sociedade Portuguesa de Electroquímica]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0872-19042009000200001</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Comparación de Metodologías Analíticas para Determinación de Aluminio en Fluidos de Hemodiálisis]]></article-title>
<article-title xml:lang="en"><![CDATA[Comparison of Analytical Methodologies for Aluminium Determination in Hemodialysis Fluids]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Quirós]]></surname>
<given-names><![CDATA[Miriam B.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Costa Rica Centro de Electroquímica y Energía Química ]]></institution>
<addr-line><![CDATA[San Pedro ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Ciudad Universitaria Rodrigo Facio  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2009</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2009</year>
</pub-date>
<volume>27</volume>
<numero>2</numero>
<fpage>69</fpage>
<lpage>76</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_arttext&amp;pid=S0872-19042009000200001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_abstract&amp;pid=S0872-19042009000200001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_pdf&amp;pid=S0872-19042009000200001&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se desarrolló y validó una metodología para cuantificar aluminio en fluidos utilizados en hemodiálisis renal, basada en la reacción de Al con cupferrón, adsorción del complejo sobre un electrodo de gota de Hg y la posterior desorción y medida de la corriente producida por la reducción del complejo. Se realizó la validación de parámetros para voltamperometría de onda cuadrada (SWV). Se determinaron también los parámetros de desempeño del método, veracidad, ámbito lineal, límite de detección, límite de cuantificación. Se aplicó a la determinación de aluminio en muestras de hemodiálisis. Se desarrolló y validó posteriormente una metodología para la determinación de aluminio en fluidos empleados en hemodiálisis renal por absorción electrotérmica. Se determinaron las mejores condiciones para el tratamiento de la muestra. También se determinaron los parámetros de desempeño del método. Esta metodología se aplicó durante un año al análisis de los fluidos de la Unidad de Hemodiálisis del Hospital México de la Caja Costarricense del Seguro Social de Costa Rica. El contenido en µg/L de la mayor parte de las muestras analizadas por ambas metodologías se encontraban sobre las recomendaciones internacionales en agua empleada en hemodiálisis.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[In order to quantifying aluminium by analyzing hemodialysis fluids, two methodologies were developed and validated: square wave adsorptive voltammetry (SWAV) and electrothermic absortion. Performance parameters were established for the two methodologies. They were both applied successfully to the analysis of hemodialysis fluids.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[aluminio]]></kwd>
<kwd lng="es"><![CDATA[hemodiálisis]]></kwd>
<kwd lng="es"><![CDATA[determinación]]></kwd>
<kwd lng="es"><![CDATA[voltametría de onda cuadrada]]></kwd>
<kwd lng="es"><![CDATA[adsorción]]></kwd>
<kwd lng="es"><![CDATA[validación]]></kwd>
<kwd lng="es"><![CDATA[absorción electrotérmica]]></kwd>
<kwd lng="en"><![CDATA[aluminium]]></kwd>
<kwd lng="en"><![CDATA[analysis]]></kwd>
<kwd lng="en"><![CDATA[hemodialysis]]></kwd>
<kwd lng="en"><![CDATA[fluids]]></kwd>
<kwd lng="en"><![CDATA[square wave voltammetry]]></kwd>
<kwd lng="en"><![CDATA[adsorptive electrothermic absorption]]></kwd>
<kwd lng="en"><![CDATA[performance parameters]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="center"><b>Comparaci&oacute;n de Metodolog&iacute;as Anal&iacute;ticas    para Determinaci&oacute;n de Aluminio en Fluidos de Hemodi&aacute;lisis</b></p>     <p align="center"><b>&nbsp;</b></p>     <p align="center"><b>Miriam B. Quirós</b><a href="#1">*</a><a name="top1"></a></p>     <p align="center"><b>&nbsp;</b></p>     <p align="center"><i>Centro de Electroquímica y Energía Química, Universidad de    Costa Rica, Apdo 2060, </i><i>San Pedro, Ciudad Universitaria Rodrigo Facio,    Costa Rica </i></p>     <p align="center">&nbsp;</p>     <p align="center">Received 25 April 2008; accepted 12 March 2009</p>     <p align="center">&nbsp;</p>     <p align="center">&nbsp;</p>     <p><b>Resumen</b></p>     ]]></body>
<body><![CDATA[<p> Se desarroll&oacute; y valid&oacute; una metodolog&iacute;a para cuantificar    aluminio en fluidos utilizados en hemodi&aacute;lisis renal, basada en la reacci&oacute;n    de Al con cupferr&oacute;n, adsorci&oacute;n del complejo sobre un electrodo    de gota de Hg y la posterior desorci&oacute;n y medida de la corriente producida    por la reducci&oacute;n del complejo. Se realiz&oacute; la validaci&oacute;n    de par&aacute;metros para voltamperometr&iacute;a de onda cuadrada (SWV). Se    determinaron tambi&eacute;n los par&aacute;metros de desempe&ntilde;o del m&eacute;todo,    veracidad, &aacute;mbito lineal, l&iacute;mite de detecci&oacute;n, l&iacute;mite    de cuantificaci&oacute;n. Se aplic&oacute; a la determinaci&oacute;n de aluminio    en muestras de hemodi&aacute;lisis.</p>     <p> Se desarroll&oacute; y valid&oacute; posteriormente una metodolog&iacute;a    para la determinaci&oacute;n de aluminio en fluidos empleados en hemodi&aacute;lisis    renal por absorci&oacute;n electrot&eacute;rmica. Se determinaron las mejores    condiciones para el tratamiento de la muestra. Tambi&eacute;n se determinaron    los par&aacute;metros de desempe&ntilde;o del m&eacute;todo. Esta metodolog&iacute;a    se aplic&oacute; durante un a&ntilde;o al an&aacute;lisis de los fluidos de    la Unidad de Hemodi&aacute;lisis del Hospital M&eacute;xico de la Caja Costarricense    del Seguro Social de Costa Rica. El contenido en &micro;g/L de la mayor parte    de las muestras analizadas por ambas metodolog&iacute;as se encontraban sobre    las recomendaciones internacionales en agua empleada en hemodi&aacute;lisis.</p>     <p> <b><i>Palabras clave</i></b>: aluminio, hemodi&aacute;lisis, determinaci&oacute;n,    voltametr&iacute;a de onda cuadrada, adsorci&oacute;n, validaci&oacute;n, absorci&oacute;n    electrot&eacute;rmica.</p>     <p>&nbsp;</p>    <p align="center">&nbsp;</p>      <p><b>Comparison of Analytical Methodologies for Aluminium Determination in Hemodialysis    Fluids</b></p>      <p><b>Abstract</b></p>      <p>In order to quantifying aluminium by analyzing hemodialysis fluids, two methodologies were developed and validated: square wave adsorptive voltammetry (SWAV) and electrothermic absortion. Performance parameters were established for the two methodologies. They were both applied successfully to the analysis of hemodialysis fluids.</p>      <p><b><i>Keywords</i></b>: aluminium, analysis, hemodialysis, fluids, square wave    voltammetry, adsorptive electrothermic absorption, performance parameters.</p>      <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>Texto disponível em PDF</p>     <p>Full text only in PDF format</p>     <p>&nbsp;</p>     <p>&nbsp;</p>      <p><b>Referencias</b></p>      <!-- ref --><p>1. R. Vanholder et al., The role of trace elements in uraemic toxicity, <i>Nephrol    Dial Transplant </i>17 [ Suppl 2] (2002) 2-8. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000029&pid=S0872-1904200900020000100001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>2. M. Barquero Quirós, R. Vargas Rojas, R Blanco-Sáenz, Neurotoxicidad y enfermedades    óseas provocadas por la contaminación con aluminio en las soluciones de diálisis    renal. <i>Rev. Costarricense de Ciencias Médicas</i> 22 (3,4) (2001) 177-189.  </p>      <!-- ref --><p>3. J. Smeyers-Verbeke, D. Verbeelen, Determination of aluminiun in dializate    concentrates by L´vov platform graphite furnace atomic absortion spectrometry,<i>    Anal. Chem.</i> 60 (1988) 380-383.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000031&pid=S0872-1904200900020000100002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4. I. Narim, M. Tuzen, M Soylac, Aluminium determination in enviromental samples    by graphite furnace atomic absortion spectrometry after solid phase extraction    on amberlite XAD- 1180/ pyrocathecol violet chelating resin, <i>Talanta</i>    63 (2004) 411-418.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000032&pid=S0872-1904200900020000100003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5. M. do S. Silva, P.B. Freire dos Reis, Determinação espectrofométrica de    alumínio em concentrados salinos utilizados en hemodiálise empregando pré-concentração    em fluxo, <i>Quim. Nova</i> 25-6 (2002) 931-934.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000033&pid=S0872-1904200900020000100004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6. M. Barquero Quirós, Biyun Z. Wu, Development and validation of an adsortive    method for aluminiun determination in fluids used in renal dialysis. <i>Portugaliae    Electrochimica Acta</i> 23 (2005) 165-178.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000034&pid=S0872-1904200900020000100005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7. M. Barquero Quirós, Desarrollo y optimización de un método voltamperométrico    adsortivo para la determinación de aluminio en agua, <i>Portugaliae Electrochimica    Acta</i> 23 (2005) 403-411.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000035&pid=S0872-1904200900020000100006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8. W. Slavin, G.R. Carnrick, D.C. Manning, Nitrate magnesium as a matrix modifier    in the stabilized temperature platform furnace, <i>Anal. Chem.</i> 54 (1982)    621-624.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000036&pid=S0872-1904200900020000100007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9. W. Slavin, G.R. Carnrick, D.C. Manning, Effect of graphite furnace substrate    materials on analysis by furnace graphite atomic absortion, <i>Anal. Chem.</i>    53 (1981) 1504-1509.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000037&pid=S0872-1904200900020000100008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10<b>. </b>A.Romero, J. Tahán, A. Moronta, Alternative Simple Mineralization    Procedures to Permit Subsequent Polarographic Determination of Total Soluble    Aluminiun in Haemodialysis Water, <i>Analytica Chimica Acta</i> 257 (1992)147.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000038&pid=S0872-1904200900020000100009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p>11. Guidelines. Section IV. Dialysis fluid Purity. <i>Nephrol. Dial. Transplant    </i>17 [Suppl 7] (2002) 45-62. </p>      <p>12. Association for Advancement of Medical Inst., Arlington, VA, AAMI American    National Standard, (1995) pp. 257-277.</p>      <p>13. P. Kerr, V. Perkovic, J. Petrie, J. Agar, A. Disney, Nephrology. Dialysis    Adequacy (HD) Guidelines. 10 (2005) S61–S80.</p>      <p>14. León R. Carlos, Tesis de Doctorado 2002, Universidad de Extremadura, España.</p>      ]]></body>
<body><![CDATA[<p>15<b>. </b>James N. Miller, Jane C. Miller, Estadistica y Quimiometría para    Química Analítica. 4<sup>a</sup>  Edición, Prentice Hall, 2002. Capítulo 5.</p>      <p>&nbsp;</p>      <p><a name="1"></a><a href="#top1">*</a> Corresponding author. E-mail address:    <a href="mailto:miriamdemorales@yahoo.com">miriamdemorales@yahoo.com</a></p>          ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vanholder]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The role of trace elements in uraemic toxicity]]></article-title>
<source><![CDATA[Nephrol Dial Transplant]]></source>
<year>2002</year>
<volume>17</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>2-8</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smeyers-Verbeke]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Verbeelen]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of aluminiun in dializate concentrates by L´vov platform graphite furnace atomic absortion spectrometry]]></article-title>
<source><![CDATA[Anal. Chem.]]></source>
<year>1988</year>
<volume>60</volume>
<page-range>380-383</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Narim]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Tuzen]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Soylac]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aluminium determination in enviromental samples by graphite furnace atomic absortion spectrometry after solid phase extraction on amberlite XAD- 1180/ pyrocathecol violet chelating resin]]></article-title>
<source><![CDATA[Talanta]]></source>
<year>2004</year>
<volume>63</volume>
<page-range>411-418</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[M. do S.]]></given-names>
</name>
<name>
<surname><![CDATA[Reis]]></surname>
<given-names><![CDATA[P.B. Freire dos]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Determinação espectrofométrica de alumínio em concentrados salinos utilizados en hemodiálise empregando pré-concentração em fluxo]]></article-title>
<source><![CDATA[Quim. Nova]]></source>
<year>2002</year>
<volume>25</volume>
<page-range>931-934</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quirós]]></surname>
<given-names><![CDATA[M. Barquero]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[Biyun Z.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Development and validation of an adsortive method for aluminiun determination in fluids used in renal dialysis]]></article-title>
<source><![CDATA[Portugaliae Electrochimica Acta]]></source>
<year>2005</year>
<volume>23</volume>
<page-range>165-178</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quirós]]></surname>
<given-names><![CDATA[M. Barquero]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Desarrollo y optimización de un método voltamperométrico adsortivo para la determinación de aluminio en agua]]></article-title>
<source><![CDATA[Portugaliae Electrochimica Acta]]></source>
<year>2005</year>
<volume>23</volume>
<page-range>403-411</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Slavin]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Carnrick]]></surname>
<given-names><![CDATA[G.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Manning]]></surname>
<given-names><![CDATA[D.C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nitrate magnesium as a matrix modifier in the stabilized temperature platform furnace]]></article-title>
<source><![CDATA[Anal. Chem.]]></source>
<year>1982</year>
<volume>54</volume>
<page-range>621-624</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Slavin]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Carnrick]]></surname>
<given-names><![CDATA[G.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Manning]]></surname>
<given-names><![CDATA[D.C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of graphite furnace substrate materials on analysis by furnace graphite atomic absortion]]></article-title>
<source><![CDATA[Anal. Chem.]]></source>
<year>1981</year>
<volume>53</volume>
<page-range>1504-1509</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Romero]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Tahán]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Moronta]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Alternative Simple Mineralization Procedures to Permit Subsequent Polarographic Determination of Total Soluble Aluminiun in Haemodialysis Water]]></article-title>
<source><![CDATA[Analytica Chimica Acta]]></source>
<year>1992</year>
<volume>257</volume>
<page-range>147</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<collab>Guidelines</collab>
<article-title xml:lang="en"><![CDATA[Section IV. Dialysis fluid Purity]]></article-title>
<source><![CDATA[Nephrol. Dial. Transplant]]></source>
<year>2002</year>
<volume>17</volume>
<page-range>45-62</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
