<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1646-706X</journal-id>
<journal-title><![CDATA[Angiologia e Cirurgia Vascular]]></journal-title>
<abbrev-journal-title><![CDATA[Angiol Cir Vasc]]></abbrev-journal-title>
<issn>1646-706X</issn>
<publisher>
<publisher-name><![CDATA[Sociedade Portuguesa de Angiologia e Cirurgia Vascular]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1646-706X2024000100038</article-id>
<article-id pub-id-type="doi">10.48750/acv572</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Fenestrated Physician-Modified Endografts (PMEGs) - a viable option for urgent cases]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bento]]></surname>
<given-names><![CDATA[Rita]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Alves]]></surname>
<given-names><![CDATA[Gonçalo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodrigues]]></surname>
<given-names><![CDATA[Gonçalo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Garcia]]></surname>
<given-names><![CDATA[Rita]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ribeiro]]></surname>
<given-names><![CDATA[Tiago]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cardoso]]></surname>
<given-names><![CDATA[Joana]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ferreira]]></surname>
<given-names><![CDATA[Rita Soares]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ferreira]]></surname>
<given-names><![CDATA[Maria Emília]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Centro Hospitalar Universitário Lisboa Central Hospital de Santa Marta Departamento Angiologia e Cirurgia Vascular]]></institution>
<addr-line><![CDATA[Lisboa ]]></addr-line>
<country>Portugal</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2024</year>
</pub-date>
<volume>20</volume>
<numero>1</numero>
<fpage>38</fpage>
<lpage>44</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_arttext&amp;pid=S1646-706X2024000100038&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_abstract&amp;pid=S1646-706X2024000100038&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.pt/scielo.php?script=sci_pdf&amp;pid=S1646-706X2024000100038&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract  Introduction: Fenestrated and branched stent graft technology has come a long way over the past few years, enabling the treatment of complex juxtarenal aneurysms, thoracoabdominal aneurysms, and arch pathologies. Many innovations have been developed, namely device and delivery optimization and technical tricks. These concepts have proven to work well when there is sufficient time to plan and manufacture a custom-made device for the patient. However, this is different in urgent or emergent cases. Using parallel graft techniques or off-the-shelf stent grafts may be efficient in urgent situations, but it is also associated with selection limitations. Recent publications have demonstrated similar mid-term technical and clinical results between physician-modified endografts (PMEGs) and customized devices. The authors aim to describe their institutional series of PMEGs.  Methods:  The clinical files of all patients undergoing PMEGs were consulted, and demographic data as surgery outcomes were collected. Technical success: creating the intended number of fenestrations, target vessel catheterization, and patency. Procedural success: technical success with adequate aneurysm exclusion and without endoleak in the final angiography. 30-day complications and mortality were also evaluated. Technical and procedural success were assessed, as well as morbidity and mortality.  Results:  Between December 2020 and December 2022, 3 patients underwent PMEGs. The indications were a juxtarenal aortic aneurysm, a type V thoracoabdominal aneurysm and a persistent type 1a endoleak. All patients were symptomatic, with one stable rupture. All cases were performed with technical and procedural success and no morbidity and mortality at 30 days.  Conclusion:  Stent graft modification is a valuable and valid tool in emergencies and should be a vascular surgeon's trump card when dealing with complex aortic pathologies. Nevertheless, due to the absence of long-term evidence, it should be reserved for acute patients unfit for open repair and in aneurysms with unfavorable anatomy for an off-the-shelf device.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Physician-modified endograft]]></kwd>
<kwd lng="en"><![CDATA[physician-modified stent graft]]></kwd>
<kwd lng="en"><![CDATA[Abdominal aortic aneurysm]]></kwd>
<kwd lng="en"><![CDATA[thoracoabdominal aortic aneurysm]]></kwd>
<kwd lng="en"><![CDATA[Juxtarenal aneurysm]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pyun]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Contemporary indications, techniques, and outcomes of physician-modified endografts for the treatment of complex abdominal and TAAA aortic aneurysms]]></article-title>
<source><![CDATA[Semin Vasc Surg]]></source>
<year>2022</year>
<volume>35</volume>
<page-range>364-73</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<collab>O'Donnell TF.Patel VI.Deery SE.Li C.Swerdlow NJ.Liang P</collab>
<article-title xml:lang=""><![CDATA[The state of complex endovascular abdominal aortic aneurysm repairs in the Vascular Quality Initiative]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>2019</year>
<volume>70</volume>
<page-range>369-80</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oderich]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and TAAA aortic aneurysms]]></article-title>
<collab>Maurício Serra Ribeiro.Sandri GA.Tenorio ER.Hofer JM.Mendes BC</collab>
<source><![CDATA[J Vasc Surg]]></source>
<year>2019</year>
<volume>70</volume>
<page-range>31-42</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Sarode]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Stern]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Harth]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[VL]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Physician-modified endografts are associated with a survival benefit over parallel grafting in TAAA aneurysms]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>2022</year>
<volume>76</volume>
<page-range>318-25</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chait]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tenorio]]></surname>
<given-names><![CDATA[ER]]></given-names>
</name>
<name>
<surname><![CDATA[Hofer]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[DeMartino]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Oderich]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Mendes]]></surname>
<given-names><![CDATA[BC]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Five-year outcomes of physician-modified endografts for repair of complex abdominal and TAAA aortic aneurysms]]></article-title>
<source><![CDATA[J Vasc Surg]]></source>
<year>2023</year>
<volume>77</volume>
<page-range>374-85</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
